Calibration and calculations
How BrewForge calibrates and converts device readings: gravity offset, Plato and Brix to SG, Fahrenheit to Celsius, pressure, weight and volume units, plausibility checks and logging interval.
BrewForge converts every reading to the same base units (specific gravity, °C, PSI, kg, liters) before storing it, so devices from different makers end up on one scale. This page lists exactly what happens to a reading, in the order it happens.
Gravity offset
If a device reads consistently high or low, set a gravity offset: on the device page, click Gravity offset under Settings (or ⋯ → Settings…). BrewForge adds it to every gravity reading, before the reading is stored or added to a brew.
The offset must be between −0.050 and +0.050. While you type, Device settings previews the latest reading with the new offset: Latest reading: sent … → saved as ….

stored gravity = reported gravity (SG) + offset
The offset is always in specific gravity, also if you display gravity in Plato. Example: the device shows 1.052 while a hydrometer sample of the same wort reads 1.050, so enter -0.002.
To find the offset, compare the device with a hydrometer or refractometer sample at the start of fermentation (refractometers need alcohol correction once fermentation has started).
The offset only applies to readings that arrive after you change it. Readings already in a brew or in Recent data keep their value. The device's latest reading is recalculated with the new offset, so Latest reading on the device page always shows the sent value plus the current offset (Includes your offset of … (sent …)).
The offset isn't offered for a Tilt Bridge (each of its Tilts has its own), a Plaato Airlock (no gravity) or a Custom Stream that doesn't map a gravity field.
Built-in device types
For iSpindel, Hydrom, Tilt, RAPT Pill, GravityMon and BrewBrain Float, BrewForge reads the unit fields of each format:
Plato → SG (when the payload says P):
SG = 260.4 / (260.4 − °P), for example 12 °P → 1.0483
Fahrenheit → Celsius (when the payload says F; for Tilt whenever it doesn't say C):
°C = (°F − 32) × 5 / 9
GravityMon without unit: a gravity above 1.200 is read as Plato.
After converting, BrewForge drops values that can't be real: gravity outside 0.800–1.200 SG and temperature outside −50 to 100 °C. The rest of the reading (for example the temperature when only the gravity was implausible) is still used.
Custom Stream unit conversions
Custom Stream devices convert with the unit you chose in the mapping (or the unit read from the payload):
| Field | From | Formula |
|---|---|---|
| Gravity | Plato | SG = 260.4 / (260.4 − °P) |
| Gravity | Brix | °P = Brix / 1.03, then SG = 260.4 / (260.4 − °P) |
| Temperature | °F | °C = (°F − 32) × 5 / 9 |
| Temperature | K | °C = K − 273.15 |
| Pressure | bar | PSI = bar × 14.5038 |
| Pressure | kPa | PSI = kPa × 0.145038 |
| Weight | g / oz / lb | kg = g / 1000, oz × 0.0283495, lb × 0.453592 |
| Volume | ml / gallons | L = ml / 1000, gal × 3.78541 |
Plato uses the same formula as the built-in device types and the calculators: 12 °P → 260.4 / 248.4 = 1.0483.
Brix is first divided by the default wort correction factor of 1.03, the same as in the unit converter: 12.4 Brix → 12.04 °P → 1.0485. There is no alcohol correction, so this is accurate for unfermented wort only; a refractometer-based sensor in fermenting beer needs its own correction before sending.
The conversion applies to readings that arrive from now on. Readings already stored keep their value.
Custom Stream values are not range-checked, so a mapping mistake (for example Plato mapped as SG) shows up as wrong values in the chart. Use Try a sample payload in the mapping to check it first.
Logging interval
Each device logs at most one reading every 14 minutes. Readings that arrive sooner still update the device's latest gravity, temperature, weight and volume, but they are not stored in Recent data and not added to a brew. The webhook response says "logged": false, "reason": "rate_limit" for them.
Set your device to send every 15 minutes or less often. More frequent readings don't add information to a fermentation curve and drain the battery.
Time of a reading
A reading is stored with the time BrewForge received it. Only Custom Stream devices can send their own measurement time (Timestamp field or ×tamp=).