BrewForge Docs

Refractometer Correction Calculator

Correct refractometer Brix readings for alcohol: original gravity, current or final gravity, attenuation and ABV with the Bonham and Terrill formulas and your wort correction factor.

A refractometer needs only a drop of wort, which makes it handy on brew day. Once fermentation starts, though, alcohol bends light differently from sugar and the Brix reading no longer tells you the gravity. This calculator corrects the reading for alcohol.

The Refractometer calculator: original Brix 12 and current Brix 6 while still fermenting give a current gravity of 2.4 °P (1.009 SG), OG 11.7 °P, 5.0% ABV and 79.3% apparent attenuation

Open it with Calculators in the sidebar → Refractometer.

Inputs

All inputs sit in the Readings section. Gravities show in your gravity unit from Settings; Brix is always °Bx, so this calculator has no Units button.

FieldWhat to enter
FermentationStill fermenting (reading still dropping, or not sure) uses Bonham's formula. Finished (reading unchanged for 2–3 days) uses Terrill's linear formula.
Original BrixThe wort reading on brew day, before pitching the yeast.
Current Brix / Final BrixThe raw number from the refractometer today. The label follows the Fermentation switch.

The Wort correction factor fold below (its title shows the current value, 1.03 by default) holds the Wort correction factor (WCF). Keep 1.03 unless you measured your own (typically 1.02–1.06, see below). Values outside 1–1.2 show a warning and no result.

The original Brix must be above zero, and the current or final Brix can't be negative or higher than the original Brix. If you added sugar during fermentation, the formulas don't apply: use a hydrometer instead.

Results

  • The big number: Current gravity (still fermenting) or Final gravity (FG) (finished), corrected for alcohol, in your gravity unit. The line below gives the other unit and which formula was used.
  • Original gravity (OG) from the original Brix, in both units. It shows as soon as you enter the original Brix.
  • ABV and Apparent attenuation from both readings.

The How it's calculated fold under the results shows the formulas.

How BrewForge corrects refractometer readings

The WCF corrects for refractometers being calibrated for sucrose: corrected Brix = Brix / WCF.

Original gravity (corrected original Brix OB): OG = 1 + OB / (258.6 − OB / 258.2 × 227.1), and OG in °P = OB.

Still fermenting (Bonham), with OB corrected and the current reading MB raw:

SG = 1.001843 − 0.002318474 × OB − 0.000007775 × OB² − 0.000000034 × OB³ + 0.00574 × MB + 0.00003344 × MB² + 0.000000086 × MB³

Finished (Terrill linear), both readings corrected:

SG = 1 − 0.00085683 × OB + 0.0034941 × MB

Results are limited to 0.990–1.200. The gravity in °P is the apparent extract from the de Clerck equation, AE = 668.72 × SG − 463.37 − 205.347 × SG², the attenuation is (1 − AE / OB) × 100 and the ABV uses the same formula as the ABV calculator, with SG as the FG.

Example: original Brix 12, current Brix 6, WCF 1.03. OB = 12 / 1.03 = 11.65, so OG = 1.047 (11.7 °P). Still fermenting: SG = 1.0094 (2.4 °P), attenuation 79.3 %, ABV 5.0 %. With Finished the same readings give SG = 1 − 0.00998 + 0.02035 = 1.0104 (2.7 °P), 77.2 % attenuation and 4.8 % ABV.

Measure your own WCF

Take a hydrometer reading and a refractometer reading of the same wort sample (cooled, before pitching). Convert the hydrometer reading to °Plato with the unit converter; your WCF is Brix / °Plato. Repeat on a few brew days and use the average.

On this page